From 530688e39c644543b71bdd9cb45fdfb458a28eaa Mon Sep 17 00:00:00 2001 From: Emil Gedenryd Date: Fri, 13 Sep 2024 11:57:02 +0200 Subject: [PATCH] iio: light: opt3001: add missing full-scale range value The opt3001 driver uses predetermined full-scale range values to determine what exponent to use for event trigger threshold values. The problem is that one of the values specified in the datasheet is missing from the implementation. This causes larger values to be scaled down to an incorrect exponent, effectively reducing the maximum settable threshold value by a factor of 2. Add missing full-scale range array value. Fixes: 94a9b7b1809f ("iio: light: add support for TI's opt3001 light sensor") Signed-off-by: Emil Gedenryd Cc: Link: https://patch.msgid.link/20240913-add_opt3002-v2-1-69e04f840360@axis.com Signed-off-by: Jonathan Cameron --- drivers/iio/light/opt3001.c | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/drivers/iio/light/opt3001.c b/drivers/iio/light/opt3001.c index 887c4b776a86..176e54bb48c3 100644 --- a/drivers/iio/light/opt3001.c +++ b/drivers/iio/light/opt3001.c @@ -138,6 +138,10 @@ static const struct opt3001_scale opt3001_scales[] = { .val = 20966, .val2 = 400000, }, + { + .val = 41932, + .val2 = 800000, + }, { .val = 83865, .val2 = 600000, -- 2.50.1