thunderbolt: Use scale field when allocating USB3 bandwidth
When tunneling aggregated USB3 (20 Gb/s) the bandwidth values that are
programmed to the ADP_USB3_CS_2 go higher than 4096 and that does not
fit anymore to the 12-bit field. Fix this by scaling the value using