]> www.infradead.org Git - users/dwmw2/esp32-pool.git/log
users/dwmw2/esp32-pool.git
14 months agoTurn pump off when it gets cold after 5pm
David Woodhouse [Thu, 9 May 2024 09:27:09 +0000 (10:27 +0100)]
Turn pump off when it gets cold after 5pm

There's still some water flow through the roof even when the bypass valve
is open. So stop pumping completely if it stays cold for more than half
an hour. But *only* after 5pm, because the pump *does* need to run for
enough hours each day to actually clean the water, and because this way
I don't need to bother with a trigger for actually turning it back on
again — if it's already cold after 5pm, it's unlikely to warm up again.

Bump the timed switch off to 8pm, because this should now be the primary
way the pump is turned off.

14 months agoDebug pump auto-on
David Woodhouse [Thu, 9 May 2024 09:03:23 +0000 (10:03 +0100)]
Debug pump auto-on

14 months agoAdjust delta for new input sensor
David Woodhouse [Thu, 9 May 2024 07:31:13 +0000 (08:31 +0100)]
Adjust delta for new input sensor

14 months agoForce bypass valve open before turning pump on in the morning
David Woodhouse [Wed, 8 May 2024 11:39:34 +0000 (12:39 +0100)]
Force bypass valve open before turning pump on in the morning

14 months agoNew solar_in sensor in new pipework
David Woodhouse [Wed, 8 May 2024 11:16:46 +0000 (12:16 +0100)]
New solar_in sensor in new pipework

17 months agoPaper working now
David Woodhouse [Wed, 14 Feb 2024 10:34:09 +0000 (10:34 +0000)]
Paper working now

18 months agoBUSY pin is inverted, not RESET
David Woodhouse [Fri, 26 Jan 2024 10:24:27 +0000 (10:24 +0000)]
BUSY pin is inverted, not RESET

18 months agoAlways turn the LEDs on
David Woodhouse [Fri, 26 Jan 2024 10:18:42 +0000 (10:18 +0000)]
Always turn the LEDs on

18 months agoAdd epaper board
David Woodhouse [Sun, 14 Jan 2024 18:13:01 +0000 (18:13 +0000)]
Add epaper board

20 months agoAdd water softener measure
David Woodhouse [Mon, 27 Nov 2023 11:06:38 +0000 (11:06 +0000)]
Add water softener measure

20 months agoAdd bathroom humidity sensor and fan control unit
David Woodhouse [Fri, 10 Nov 2023 12:24:42 +0000 (12:24 +0000)]
Add bathroom humidity sensor and fan control unit

20 months agoFilter out zero temperatures too
David Woodhouse [Fri, 10 Nov 2023 12:24:21 +0000 (12:24 +0000)]
Filter out zero temperatures too

22 months agoMake it 0.2°C adjustment
David Woodhouse [Fri, 8 Sep 2023 16:41:54 +0000 (17:41 +0100)]
Make it 0.2°C adjustment

22 months agoAdjust output temp to reduce hysteresis
David Woodhouse [Fri, 8 Sep 2023 15:54:31 +0000 (16:54 +0100)]
Adjust output temp to reduce hysteresis

22 months agoPump default setting is only done if the time was valid
David Woodhouse [Wed, 6 Sep 2023 19:23:19 +0000 (20:23 +0100)]
Pump default setting is only done if the time was valid

22 months agoMake scripts for sending values to Domoticz, send on startup too
David Woodhouse [Wed, 6 Sep 2023 16:18:53 +0000 (17:18 +0100)]
Make scripts for sending values to Domoticz, send on startup too

A bunch of switches are reset to a default state on startup; make sure we
tell Domoticz about it.

22 months agoFix default setting of pump
David Woodhouse [Wed, 6 Sep 2023 13:15:58 +0000 (14:15 +0100)]
Fix default setting of pump

Make a script which turns the pool pump on or off depending on whether
the time is between 7am and 7pm. Run it at 7am and 7pm.

Also run it on time sync, and on startup, to ensure that the pump is
running if it's supposed to be after a reboot.

The 'force' parameter ensures that we don't keep flipping it on at every
time sync; only at startup and at the regular 7am/7pm switches. So if
it's been overridden manually it should stay that way without surprises.

22 months agoReport BLE-YC01 battery to Domotiz
David Woodhouse [Wed, 6 Sep 2023 11:35:37 +0000 (12:35 +0100)]
Report BLE-YC01 battery to Domotiz

22 months agoTurn pump on/off at 7
David Woodhouse [Wed, 6 Sep 2023 11:33:19 +0000 (12:33 +0100)]
Turn pump on/off at 7

22 months agoDomoticz notification for mains switches
David Woodhouse [Tue, 5 Sep 2023 21:00:31 +0000 (22:00 +0100)]
Domoticz notification for mains switches

22 months agoAdd mains relay switches
David Woodhouse [Tue, 5 Sep 2023 20:48:17 +0000 (21:48 +0100)]
Add mains relay switches

Move the 1wire power relay to GPIO12 because that doesn't offend the
strapping, while the mains relay seems to pull it up?

23 months agoFirst import
David Woodhouse [Tue, 8 Aug 2023 19:48:32 +0000 (20:48 +0100)]
First import