From: Jan Kiszka Date: Wed, 4 Sep 2019 06:42:30 +0000 (+0200) Subject: platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table X-Git-Tag: v5.4-rc1~166^2~21 X-Git-Url: https://www.infradead.org/git/?a=commitdiff_plain;h=ad0d315b4d4e7138f43acf03308192ec00e9614d;p=linux.git platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table The SIMATIC IPC227E uses the PMC clock for on-board components and gets stuck during boot if the clock is disabled. Therefore, add this device to the critical systems list. Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") Signed-off-by: Jan Kiszka Signed-off-by: Andy Shevchenko --- diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c index aa53648a2214..9aca5e7ce6d0 100644 --- a/drivers/platform/x86/pmc_atom.c +++ b/drivers/platform/x86/pmc_atom.c @@ -415,6 +415,13 @@ static const struct dmi_system_id critclk_systems[] = { DMI_MATCH(DMI_BOARD_NAME, "CB6363"), }, }, + { + .ident = "SIMATIC IPC227E", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"), + DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"), + }, + }, { /*sentinel*/ } };