From: Matthias Schiffer Date: Fri, 16 Sep 2022 11:09:55 +0000 (+0200) Subject: serial: 8250: omap: Use serial8250_em485_supported X-Git-Tag: v6.0-rc7~8^2~1 X-Git-Url: https://www.infradead.org/git/?a=commitdiff_plain;h=1e005bfae83290f6673f8213a418cc0e12868c2d;p=users%2Fdwmw2%2Flinux.git serial: 8250: omap: Use serial8250_em485_supported 8250_omap uses em485, fill in rs485_supported accordingly. This makes RS485 work with 8250_omap again, which was broken with the introduction of the RS485 config sanitization. Fixes: be2e2cb1d2819 ("serial: Sanitize rs485_struct") Reviewed-by: Ilpo Järvinen Signed-off-by: Matthias Schiffer Link: https://lore.kernel.org/r/20220916110955.161099-1-matthias.schiffer@ew.tq-group.com Signed-off-by: Greg Kroah-Hartman --- diff --git a/drivers/tty/serial/8250/8250_omap.c b/drivers/tty/serial/8250/8250_omap.c index 0dcecbbc3967a..f7fbef83583c8 100644 --- a/drivers/tty/serial/8250/8250_omap.c +++ b/drivers/tty/serial/8250/8250_omap.c @@ -1334,6 +1334,7 @@ static int omap8250_probe(struct platform_device *pdev) up.port.throttle = omap_8250_throttle; up.port.unthrottle = omap_8250_unthrottle; up.port.rs485_config = serial8250_em485_config; + up.port.rs485_supported = serial8250_em485_supported; up.rs485_start_tx = serial8250_em485_start_tx; up.rs485_stop_tx = serial8250_em485_stop_tx; up.port.has_sysrq = IS_ENABLED(CONFIG_SERIAL_8250_CONSOLE);