The test in mlx4_load_one() to remove MLX4_FLAG_MSI_X expects mlx4_NOP() to
fail with -EBUSY. It is also necessary to avoid the reset since the device
is not fully reinitialized before calling mlx4_start_hca() a second time.
Note that this will also affect mlx4_test_interrupts(), the only other user
of MLX4_CMD_NOP.
Fixes: f5aef5a ("net/mlx4_core: Activate reset flow upon fatal command cases")
Signed-off-by: Benjamin Poirier <bpoirier@suse.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
                                         msecs_to_jiffies(timeout))) {
                mlx4_warn(dev, "command 0x%x timed out (go bit not cleared)\n",
                          op);
-               err = -EIO;
-               goto out_reset;
+               if (op == MLX4_CMD_NOP) {
+                       err = -EBUSY;
+                       goto out;
+               } else {
+                       err = -EIO;
+                       goto out_reset;
+               }
        }
 
        err = context->result;