Optional properties:
 - clock-output-names   : Should contain name for output clock.
+- rohm,reset-snvs-powered : Transfer BD718x7 to SNVS state at reset.
+
+The BD718x7 supports two different HW states as reset target states. States
+are called as SNVS and READY. At READY state all the PMIC power outputs go
+down and OTP is reload. At the SNVS state all other logic and external
+devices apart from the SNVS power domain are shut off. Please refer to NXP
+i.MX8 documentation for further information regarding SNVS state. When a
+reset is done via SNVS state the PMIC OTP data is not reload. This causes
+power outputs that have been under SW control to stay down when reset has
+switched power state to SNVS. If reset is done via READY state the power
+outputs will be returned to HW control by OTP loading. Thus the reset
+target state is set to READY by default. If SNVS state is used the boot
+crucial regulators must have the regulator-always-on and regulator-boot-on
+properties set in regulator node.
 
 Example:
 
                #clock-cells = <0>;
                clocks = <&osc 0>;
                clock-output-names = "bd71837-32k-out";
+               rohm,reset-snvs-powered;
 
                regulators {
                        buck1: BUCK1 {
                                regulator-min-microvolt = <700000>;
                                regulator-max-microvolt = <1300000>;
                                regulator-boot-on;
+                               regulator-always-on;
                                regulator-ramp-delay = <1250>;
                        };
+                       // [...]
                };
        };
 
 
 LDO1, LDO2, LDO3, LDO4, LDO5, LDO6
 
 Optional properties:
+- rohm,dvs-run-voltage         : PMIC default "RUN" state voltage in uV.
+                                 See below table for bucks which support this.
+- rohm,dvs-idle-voltage                : PMIC default "IDLE" state voltage in uV.
+                                 See below table for bucks which support this.
+- rohm,dvs-suspend-voltage     : PMIC default "SUSPEND" state voltage in uV.
+                                 See below table for bucks which support this.
 - Any optional property defined in bindings/regulator/regulator.txt
 
+Supported default DVS states:
+
+BD71837:
+buck   | dvs-run-voltage       | dvs-idle-voltage      | dvs-suspend-voltage
+-----------------------------------------------------------------------------
+1      | supported             | supported             | supported
+----------------------------------------------------------------------------
+2      | supported             | supported             | not supported
+----------------------------------------------------------------------------
+3      | supported             | not supported         | not supported
+----------------------------------------------------------------------------
+4      | supported             | not supported         | not supported
+----------------------------------------------------------------------------
+rest   | not supported         | not supported         | not supported
+
+BD71847:
+buck   | dvs-run-voltage       | dvs-idle-voltage      | dvs-suspend-voltage
+-----------------------------------------------------------------------------
+1      | supported             | supported             | supported
+----------------------------------------------------------------------------
+2      | supported             | supported             | not supported
+----------------------------------------------------------------------------
+rest   | not supported         | not supported         | not supported
+
 Example:
 regulators {
        buck1: BUCK1 {
                regulator-min-microvolt = <700000>;
                regulator-max-microvolt = <1300000>;
                regulator-boot-on;
+               regulator-always-on;
                regulator-ramp-delay = <1250>;
+               rohm,dvs-run-voltage = <900000>;
+               rohm,dvs-idle-voltage = <850000>;
+               rohm,dvs-suspend-voltage = <800000>;
        };
        buck2: BUCK2 {
                regulator-name = "buck2";
                regulator-boot-on;
                regulator-always-on;
                regulator-ramp-delay = <1250>;
+               rohm,dvs-run-voltage = <1000000>;
+               rohm,dvs-idle-voltage = <900000>;
        };
        buck3: BUCK3 {
                regulator-name = "buck3";
                regulator-min-microvolt = <700000>;
                regulator-max-microvolt = <1300000>;
                regulator-boot-on;
+               rohm,dvs-run-voltage = <1000000>;
        };
        buck4: BUCK4 {
                regulator-name = "buck4";
                regulator-min-microvolt = <700000>;
                regulator-max-microvolt = <1300000>;
                regulator-boot-on;
+               rohm,dvs-run-voltage = <1000000>;
        };
        buck5: BUCK5 {
                regulator-name = "buck5";