Currently we are reporting the button state as inverted on all boards with
an axp209 pmic, tested on a ba10-tvbox, bananapi, bananapro, cubietruck and
utoo-p66 tablet.
The axp209 datasheet clearly states that the power button must be connected
between the PWRON key and ground. Which means that on a press we will get
a falling edge (dbf) irq not a rising one, and likewise on release we will
get a rising edge (dbr) irq, not a falling one.
This commit swaps the check for the 2 irqs fixing the inverted reporting of
the power button state.
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Acked-by: Chen-Yu Tsai <wens@csie.org>
Acked-by: Carlo Caione <carlo@caione.org>
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
        struct input_dev *idev = pwr;
        struct axp20x_pek *axp20x_pek = input_get_drvdata(idev);
 
-       if (irq == axp20x_pek->irq_dbr)
+       /*
+        * The power-button is connected to ground so a falling edge (dbf)
+        * means it is pressed.
+        */
+       if (irq == axp20x_pek->irq_dbf)
                input_report_key(idev, KEY_POWER, true);
-       else if (irq == axp20x_pek->irq_dbf)
+       else if (irq == axp20x_pek->irq_dbr)
                input_report_key(idev, KEY_POWER, false);
 
        input_sync(idev);