The CSI data format was being programmed incorrectly for the
1x16 media bus formats. The CSI data format for 16-bit must
be bayer/generic (CSI_SENS_CONF_DATA_FMT_BAYER).
Suggested-by: Carsten Resch <Carsten.Resch@de.bosch.com>
Signed-off-by: Steve Longerbeam <steve_longerbeam@mentor.com>
Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de>
                cfg->data_width = IPU_CSI_DATA_WIDTH_8;
                break;
        case MEDIA_BUS_FMT_UYVY8_1X16:
-               cfg->data_fmt = CSI_SENS_CONF_DATA_FMT_YUV422_UYVY;
-               cfg->mipi_dt = MIPI_DT_YUV422;
-               cfg->data_width = IPU_CSI_DATA_WIDTH_16;
-               break;
        case MEDIA_BUS_FMT_YUYV8_1X16:
-               cfg->data_fmt = CSI_SENS_CONF_DATA_FMT_YUV422_YUYV;
+               cfg->data_fmt = CSI_SENS_CONF_DATA_FMT_BAYER;
                cfg->mipi_dt = MIPI_DT_YUV422;
                cfg->data_width = IPU_CSI_DATA_WIDTH_16;
                break;