return -EMSGSIZE;
 }
 
+static void devlink_param_notify(struct devlink *devlink,
+                                struct devlink_param_item *param_item,
+                                enum devlink_command cmd)
+{
+       struct sk_buff *msg;
+       int err;
+
+       WARN_ON(cmd != DEVLINK_CMD_PARAM_NEW && cmd != DEVLINK_CMD_PARAM_DEL);
+
+       msg = nlmsg_new(NLMSG_DEFAULT_SIZE, GFP_KERNEL);
+       if (!msg)
+               return;
+       err = devlink_nl_param_fill(msg, devlink, param_item, cmd, 0, 0, 0);
+       if (err) {
+               nlmsg_free(msg);
+               return;
+       }
+
+       genlmsg_multicast_netns(&devlink_nl_family, devlink_net(devlink),
+                               msg, 0, DEVLINK_MCGRP_CONFIG, GFP_KERNEL);
+}
+
 static int devlink_nl_cmd_param_get_dumpit(struct sk_buff *msg,
                                           struct netlink_callback *cb)
 {
                        return err;
        }
 
+       devlink_param_notify(devlink, param_item, DEVLINK_CMD_PARAM_NEW);
        return 0;
 }
 
        param_item->param = param;
 
        list_add_tail(¶m_item->list, &devlink->param_list);
+       devlink_param_notify(devlink, param_item, DEVLINK_CMD_PARAM_NEW);
        return 0;
 }
 
        param_item = devlink_param_find_by_name(&devlink->param_list,
                                                param->name);
        WARN_ON(!param_item);
+       devlink_param_notify(devlink, param_item, DEVLINK_CMD_PARAM_DEL);
        list_del(¶m_item->list);
        kfree(param_item);
 }
        param_item->driverinit_value = init_val;
        param_item->driverinit_value_valid = true;
 
+       devlink_param_notify(devlink, param_item, DEVLINK_CMD_PARAM_NEW);
        return 0;
 }
 EXPORT_SYMBOL_GPL(devlink_param_driverinit_value_set);
 
+/**
+ *     devlink_param_value_changed - notify devlink on a parameter's value
+ *                                   change. Should be called by the driver
+ *                                   right after the change.
+ *
+ *     @devlink: devlink
+ *     @param_id: parameter ID
+ *
+ *     This function should be used by the driver to notify devlink on value
+ *     change, excluding driverinit configuration mode.
+ *     For driverinit configuration mode driver should use the function
+ *     devlink_param_driverinit_value_set() instead.
+ */
+void devlink_param_value_changed(struct devlink *devlink, u32 param_id)
+{
+       struct devlink_param_item *param_item;
+
+       param_item = devlink_param_find_by_id(&devlink->param_list, param_id);
+       WARN_ON(!param_item);
+
+       devlink_param_notify(devlink, param_item, DEVLINK_CMD_PARAM_NEW);
+}
+EXPORT_SYMBOL_GPL(devlink_param_value_changed);
+
 static int __init devlink_module_init(void)
 {
        return genl_register_family(&devlink_nl_family);