thermal: gov_bang_bang: Relocate regulation logic description
authorRafael J. Wysocki <rafael.j.wysocki@intel.com>
Thu, 16 Jan 2025 19:31:11 +0000 (20:31 +0100)
committerRafael J. Wysocki <rafael.j.wysocki@intel.com>
Fri, 17 Jan 2025 17:48:58 +0000 (18:48 +0100)
Move the regulation logic description from the bang_bang_trip_crossed()
kerneldoc to the preamble.

No functional impact.

Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Link: https://patch.msgid.link/4987649.31r3eYUQgx@rjwysocki.net
[ rjw: Removed a trailing whitespace ]
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
drivers/thermal/gov_bang_bang.c

index c24c168577f212f7ff7f76d2d2eb9b8acabc8680..20d4e0940eca101450638a6b0adc1cc7d3bd1b83 100644 (file)
@@ -7,6 +7,27 @@
  *  Based on step_wise.c with following Copyrights:
  *  Copyright (C) 2012 Intel Corp
  *  Copyright (C) 2012 Durgadoss R <durgadoss.r@intel.com>
+ *
+ * Regulation Logic: a two point regulation, deliver cooling state depending
+ * on the previous state shown in this diagram:
+ *
+ *                Fan:   OFF    ON
+ *
+ *                              |
+ *                              |
+ *          trip_temp:    +---->+
+ *                        |     |        ^
+ *                        |     |        |
+ *                        |     |   Temperature
+ * (trip_temp - hyst):    +<----+
+ *                        |
+ *                        |
+ *                        |
+ *
+ *   * If the fan is not running and temperature exceeds trip_temp, the fan
+ *     gets turned on.
+ *   * In case the fan is running, temperature must fall below
+ *     (trip_temp - hyst) so that the fan gets turned off again.
  */
 
 #include <linux/thermal.h>
@@ -38,28 +59,6 @@ static void bang_bang_set_instance_target(struct thermal_instance *instance,
  * @tz: thermal_zone_device
  * @trip: the trip point
  * @crossed_up: whether or not the trip has been crossed on the way up
- *
- * Regulation Logic: a two point regulation, deliver cooling state depending
- * on the previous state shown in this diagram:
- *
- *                Fan:   OFF    ON
- *
- *                              |
- *                              |
- *          trip_temp:    +---->+
- *                        |     |        ^
- *                        |     |        |
- *                        |     |   Temperature
- * (trip_temp - hyst):    +<----+
- *                        |
- *                        |
- *                        |
- *
- *   * If the fan is not running and temperature exceeds trip_temp, the fan
- *     gets turned on.
- *   * In case the fan is running, temperature must fall below
- *     (trip_temp - hyst) so that the fan gets turned off again.
- *
  */
 static void bang_bang_trip_crossed(struct thermal_zone_device *tz,