DVBv5 BER is calculated anyway, so just return it for legacy
read_ber() API too.
Signed-off-by: Antti Palosaari <crope@iki.fi>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
        fe_status_t fe_status;
        u32 ber;
        u32 ucb;
+       u64 post_bit_error_prev; /* for old read_ber we return (curr - prev) */
        u64 post_bit_error;
        u64 post_bit_count;
        u64 error_block_count;
 static int af9033_read_ber(struct dvb_frontend *fe, u32 *ber)
 {
        struct af9033_dev *dev = fe->demodulator_priv;
-       int ret;
-
-       ret = af9033_update_ch_stat(dev);
-       if (ret < 0)
-               return ret;
 
-       *ber = dev->ber;
+       *ber = (dev->post_bit_error - dev->post_bit_error_prev);
+       dev->post_bit_error_prev = dev->post_bit_error;
 
        return 0;
 }