In v3.2 the Analog Devices AD7314 temperature sensor driver was removed
as an IIO driver and added as a HWMON driver. But it was apparently
overlooked to rename two references to CONFIG_AD7314 to
CONFIG_SENSORS_AD7314. Do so now. Use the IS_ENABLED() macro, while
we're at it.
Signed-off-by: Paul Bolle <pebolle@tiscali.nl>
 };
 #endif
 
-#if defined(CONFIG_AD7314) || defined(CONFIG_AD7314_MODULE)
+#if IS_ENABLED(CONFIG_SENSORS_AD7314)
 static struct bfin5xx_spi_chip ad7314_spi_chip_info = {
        .enable_dma = 0,
 };
        },
 #endif
 
-#if defined(CONFIG_AD7314) || defined(CONFIG_AD7314_MODULE)
+#if IS_ENABLED(CONFIG_SENSORS_AD7314)
        {
                .modalias = "ad7314",
                .max_speed_hz = 1000000,