RAID5 and RAID6 profile store one copy of the data, not 2 or 3. These
values are not yet used anywhere so there's no change.
Reviewed-by: Nikolay Borisov <nborisov@suse.com>
Signed-off-by: Hans van Kranenburg <hans.van.kranenburg@mendix.com>
Signed-off-by: David Sterba <dsterba@suse.com>
                .devs_min       = 2,
                .tolerated_failures = 1,
                .devs_increment = 1,
-               .ncopies        = 2,
+               .ncopies        = 1,
                .raid_name      = "raid5",
                .bg_flag        = BTRFS_BLOCK_GROUP_RAID5,
                .mindev_error   = BTRFS_ERROR_DEV_RAID5_MIN_NOT_MET,
                .devs_min       = 3,
                .tolerated_failures = 2,
                .devs_increment = 1,
-               .ncopies        = 3,
+               .ncopies        = 1,
                .raid_name      = "raid6",
                .bg_flag        = BTRFS_BLOCK_GROUP_RAID6,
                .mindev_error   = BTRFS_ERROR_DEV_RAID6_MIN_NOT_MET,