The current code assumes that only the ramp_delay is used to determine
the time needed for the voltage to stabilize. This may be true for the
calculation done by regulator_set_voltage_time_sel(), however regulators
can implement their own set_voltage_time_sel() op which would be skipped
if no ramp delay is specified. Remove the check in
_regulator_do_set_voltage(), the functions calculating the ramp delay
return 0 anyway when the ramp delay is not configured.
Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
                goto out;
 
        /* Call set_voltage_time_sel if successfully obtained old_selector */
-       if (!rdev->constraints->ramp_disable && old_selector >= 0
-               && old_selector != selector) {
-
+       if (!old_selector >= 0 && old_selector != selector) {
                delay = ops->set_voltage_time_sel(rdev,
                                                old_selector, selector);
                if (delay < 0) {
        else if (rdev->desc->ramp_delay)
                ramp_delay = rdev->desc->ramp_delay;
 
-       if (ramp_delay == 0) {
-               rdev_warn(rdev, "ramp_delay not set\n");
+       if (ramp_delay == 0)
                return 0;
-       }
 
        /* sanity check */
        if (!rdev->desc->ops->list_voltage)