return sta;
 }
 
-/** mesh_set_ht_prot_mode - set correct HT protection mode
+/*
+ * mesh_set_ht_prot_mode - set correct HT protection mode
  *
- * Section 9.23.3.5 of IEEE 80211s standard describes the protection rules for
- * HT mesh STA in a MBSS. Three HT protection modes are supported for now,
- * non-HT mixed mode, 20MHz-protection and no-protection mode. non-HT mixed
- * mode is selected if any non-HT peers are present in our MBSS.
- * 20MHz-protection mode is selected if all peers in our 20/40MHz MBSS support
- * HT and atleast one HT20 peer is present. Otherwise no-protection mode is
- * selected.
+ * Section 9.23.3.5 of IEEE 80211-2012 describes the protection rules for HT
+ * mesh STA in a MBSS. Three HT protection modes are supported for now, non-HT
+ * mixed mode, 20MHz-protection and no-protection mode. non-HT mixed mode is
+ * selected if any non-HT peers are present in our MBSS.  20MHz-protection mode
+ * is selected if all peers in our 20/40MHz MBSS support HT and atleast one
+ * HT20 peer is present. Otherwise no-protection mode is selected.
  */
 static u32 mesh_set_ht_prot_mode(struct ieee80211_sub_if_data *sdata)
 {
 
        rcu_read_lock();
        list_for_each_entry_rcu(sta, &local->sta_list, list) {
-               if (sdata == sta->sdata &&
-                   sta->plink_state == NL80211_PLINK_ESTAB) {
-                       switch (sta->ch_type) {
-                       case NL80211_CHAN_NO_HT:
-                               mpl_dbg("mesh_plink %pM: nonHT sta (%pM) is present",
-                                       sdata->vif.addr, sta->sta.addr);
-                               non_ht_sta = true;
-                               goto out;
-                       case NL80211_CHAN_HT20:
-                               mpl_dbg("mesh_plink %pM: HT20 sta (%pM) is present",
-                                       sdata->vif.addr, sta->sta.addr);
-                               ht20_sta = true;
-                       default:
-                               break;
-                       }
+               if (sdata != sta->sdata ||
+                   sta->plink_state != NL80211_PLINK_ESTAB)
+                       continue;
+
+               switch (sta->ch_type) {
+               case NL80211_CHAN_NO_HT:
+                       mpl_dbg("mesh_plink %pM: nonHT sta (%pM) is present",
+                               sdata->vif.addr, sta->sta.addr);
+                       non_ht_sta = true;
+                       goto out;
+               case NL80211_CHAN_HT20:
+                       mpl_dbg("mesh_plink %pM: HT20 sta (%pM) is present",
+                               sdata->vif.addr, sta->sta.addr);
+                       ht20_sta = true;
+               default:
+                       break;
                }
        }
 out: