+.. SPDX-License-Identifier: GPL-2.0
 
-    D-Link DL2000-based Gigabit Ethernet Adapter Installation
-    for Linux
-    May 23, 2002
+=========================================================
+D-Link DL2000-based Gigabit Ethernet Adapter Installation
+=========================================================
+
+May 23, 2002
+
+.. Contents
 
-Contents
-========
  - Compatibility List
  - Quick Install
  - Compiling the Driver
 
 
 Compatibility List
-=================
+==================
+
 Adapter Support:
 
-D-Link DGE-550T Gigabit Ethernet Adapter.
-D-Link DGE-550SX Gigabit Ethernet Adapter.
-D-Link DL2000-based Gigabit Ethernet Adapter.
+- D-Link DGE-550T Gigabit Ethernet Adapter.
+- D-Link DGE-550SX Gigabit Ethernet Adapter.
+- D-Link DL2000-based Gigabit Ethernet Adapter.
 
 
 The driver support Linux kernel 2.4.7 later. We had tested it
 
 Quick Install
 =============
-Install linux driver as following command:
+Install linux driver as following command::
+
+    1. make all
+    2. insmod dl2k.ko
+    3. ifconfig eth0 up 10.xxx.xxx.xxx netmask 255.0.0.0
+                       ^^^^^^^^^^^^^^^\            ^^^^^^^^\
+                                       IP                   NETMASK
 
-1. make all
-2. insmod dl2k.ko
-3. ifconfig eth0 up 10.xxx.xxx.xxx netmask 255.0.0.0
-                   ^^^^^^^^^^^^^^^\        ^^^^^^^^\
-                                   IP               NETMASK
 Now eth0 should active, you can test it by "ping" or get more information by
 "ifconfig". If tested ok, continue the next step.
 
-4. cp dl2k.ko /lib/modules/`uname -r`/kernel/drivers/net
-5. Add the following line to /etc/modprobe.d/dl2k.conf:
+4. ``cp dl2k.ko /lib/modules/`uname -r`/kernel/drivers/net``
+5. Add the following line to /etc/modprobe.d/dl2k.conf::
+
        alias eth0 dl2k
-6. Run depmod to updated module indexes.
-7. Run "netconfig" or "netconf" to create configuration script ifcfg-eth0
+
+6. Run ``depmod`` to updated module indexes.
+7. Run ``netconfig`` or ``netconf`` to create configuration script ifcfg-eth0
    located at /etc/sysconfig/network-scripts or create it manually.
+
    [see - Configuration Script Sample]
 8. Driver will automatically load and configure at next boot time.
 
 Compiling the Driver
 ====================
-  In Linux, NIC drivers are most commonly configured as loadable modules.
+In Linux, NIC drivers are most commonly configured as loadable modules.
 The approach of building a monolithic kernel has become obsolete. The driver
 can be compiled as part of a monolithic kernel, but is strongly discouraged.
 The remainder of this section assumes the driver is built as a loadable module.
 CD-ROM drive
 ------------
 
-[root@XXX /] mkdir cdrom
-[root@XXX /] mount -r -t iso9660 -o conv=auto /dev/cdrom /cdrom
-[root@XXX /] cd root
-[root@XXX /root] mkdir dl2k
-[root@XXX /root] cd dl2k
-[root@XXX dl2k] cp /cdrom/linux/dl2k.tgz /root/dl2k
-[root@XXX dl2k] tar xfvz dl2k.tgz
-[root@XXX dl2k] make all
+::
+
+    [root@XXX /] mkdir cdrom
+    [root@XXX /] mount -r -t iso9660 -o conv=auto /dev/cdrom /cdrom
+    [root@XXX /] cd root
+    [root@XXX /root] mkdir dl2k
+    [root@XXX /root] cd dl2k
+    [root@XXX dl2k] cp /cdrom/linux/dl2k.tgz /root/dl2k
+    [root@XXX dl2k] tar xfvz dl2k.tgz
+    [root@XXX dl2k] make all
 
 Floppy disc drive
 -----------------
 
-[root@XXX /] cd root
-[root@XXX /root] mkdir dl2k
-[root@XXX /root] cd dl2k
-[root@XXX dl2k] mcopy a:/linux/dl2k.tgz /root/dl2k
-[root@XXX dl2k] tar xfvz dl2k.tgz
-[root@XXX dl2k] make all
+::
+
+    [root@XXX /] cd root
+    [root@XXX /root] mkdir dl2k
+    [root@XXX /root] cd dl2k
+    [root@XXX dl2k] mcopy a:/linux/dl2k.tgz /root/dl2k
+    [root@XXX dl2k] tar xfvz dl2k.tgz
+    [root@XXX dl2k] make all
 
 Installing the Driver
 =====================
 
-  Manual Installation
-  -------------------
+Manual Installation
+-------------------
+
   Once the driver has been compiled, it must be loaded, enabled, and bound
   to a protocol stack in order to establish network connectivity. To load a
-  module enter the command:
+  module enter the command::
+
+    insmod dl2k.o
+
+  or::
+
+    insmod dl2k.o <optional parameter> ; add parameter
 
-  insmod dl2k.o
+---------------------------------------------------------
 
-  or
+  example::
 
-  insmod dl2k.o <optional parameter>   ; add parameter
+    insmod dl2k.o media=100mbps_hd
 
-  ===============================================================
-   example: insmod dl2k.o media=100mbps_hd
-   or      insmod dl2k.o media=3
-   or      insmod dl2k.o media=3,2     ; for 2 cards
-  ===============================================================
+   or::
+
+    insmod dl2k.o media=3
+
+   or::
+
+    insmod dl2k.o media=3,2    ; for 2 cards
+
+---------------------------------------------------------
 
   Please reference the list of the command line parameters supported by
   the Linux device driver below.
 
   The insmod command only loads the driver and gives it a name of the form
   eth0, eth1, etc. To bring the NIC into an operational state,
-  it is necessary to issue the following command:
+  it is necessary to issue the following command::
 
-  ifconfig eth0 up
+    ifconfig eth0 up
 
   Finally, to bind the driver to the active protocol (e.g., TCP/IP with
-  Linux), enter the following command:
+  Linux), enter the following command::
 
-  ifup eth0
+    ifup eth0
 
   Note that this is meaningful only if the system can find a configuration
   script that contains the necessary network information. A sample will be
   given in the next paragraph.
 
-  The commands to unload a driver are as follows:
+  The commands to unload a driver are as follows::
 
-  ifdown eth0
-  ifconfig eth0 down
-  rmmod dl2k.o
+    ifdown eth0
+    ifconfig eth0 down
+    rmmod dl2k.o
 
   The following are the commands to list the currently loaded modules and
-  to see the current network configuration.
+  to see the current network configuration::
 
-  lsmod
-  ifconfig
+    lsmod
+    ifconfig
 
 
-  Automated Installation
-  ----------------------
+Automated Installation
+----------------------
   This section describes how to install the driver such that it is
   automatically loaded and configured at boot time. The following description
   is based on a Red Hat 6.0/7.0 distribution, but it can easily be ported to
   other distributions as well.
 
-  Red Hat v6.x/v7.x
-  -----------------
+Red Hat v6.x/v7.x
+-----------------
   1. Copy dl2k.o to the network modules directory, typically
      /lib/modules/2.x.x-xx/net or /lib/modules/2.x.x/kernel/drivers/net.
   2. Locate the boot module configuration file, most commonly in the
-     /etc/modprobe.d/ directory. Add the following lines:
+     /etc/modprobe.d/ directory. Add the following lines::
 
-     alias ethx dl2k
-     options dl2k <optional parameters>
+       alias ethx dl2k
+       options dl2k <optional parameters>
 
      where ethx will be eth0 if the NIC is the only ethernet adapter, eth1 if
      one other ethernet adapter is installed, etc. Refer to the table in the
 Linux device
 driver.
 
-mtu=packet_size                        - Specifies the maximum packet size. default
+
+===============================   ==============================================
+mtu=packet_size                          Specifies the maximum packet size. default
                                  is 1500.
 
-media=media_type               - Specifies the media type the NIC operates at.
+media=media_type                 Specifies the media type the NIC operates at.
                                  autosense     Autosensing active media.
+
+                                 ===========   =========================
                                  10mbps_hd     10Mbps half duplex.
                                  10mbps_fd     10Mbps full duplex.
                                  100mbps_hd    100Mbps half duplex.
                                  4             100Mbps full duplex.
                                  5             1000Mbps half duplex.
                                  6             1000Mbps full duplex.
+                                 ===========   =========================
 
                                  By default, the NIC operates at autosense.
                                  1000mbps_fd and 1000mbps_hd types are only
                                  available for fiber adapter.
 
-vlan=n                         - Specifies the VLAN ID. If vlan=0, the
+vlan=n                           Specifies the VLAN ID. If vlan=0, the
                                  Virtual Local Area Network (VLAN) function is
                                  disable.
 
-jumbo=[0|1]                    - Specifies the jumbo frame support. If jumbo=1,
+jumbo=[0|1]                      Specifies the jumbo frame support. If jumbo=1,
                                  the NIC accept jumbo frames. By default, this
                                  function is disabled.
                                  Jumbo frame usually improve the performance
                                  int gigabit.
-                                 This feature need jumbo frame compatible 
+                                 This feature need jumbo frame compatible
                                  remote.
-                                 
-rx_coalesce=m                  - Number of rx frame handled each interrupt.
-rx_timeout=n                   - Rx DMA wait time for an interrupt. 
-                                 If set rx_coalesce > 0, hardware only assert 
-                                 an interrupt for m frames. Hardware won't 
+
+rx_coalesce=m                    Number of rx frame handled each interrupt.
+rx_timeout=n                     Rx DMA wait time for an interrupt.
+                                 If set rx_coalesce > 0, hardware only assert
+                                 an interrupt for m frames. Hardware won't
                                  assert rx interrupt until m frames received or
-                                 reach timeout of n * 640 nano seconds. 
-                                 Set proper rx_coalesce and rx_timeout can 
+                                 reach timeout of n * 640 nano seconds.
+                                 Set proper rx_coalesce and rx_timeout can
                                  reduce congestion collapse and overload which
                                  has been a bottleneck for high speed network.
-                                 
+
                                  For example, rx_coalesce=10 rx_timeout=800.
-                                 that is, hardware assert only 1 interrupt 
-                                 for 10 frames received or timeout of 512 us. 
+                                 that is, hardware assert only 1 interrupt
+                                 for 10 frames received or timeout of 512 us.
 
-tx_coalesce=n                  - Number of tx frame handled each interrupt.
-                                 Set n > 1 can reduce the interrupts 
+tx_coalesce=n                    Number of tx frame handled each interrupt.
+                                 Set n > 1 can reduce the interrupts
                                  congestion usually lower performance of
                                  high speed network card. Default is 16.
-                                 
-tx_flow=[1|0]                  - Specifies the Tx flow control. If tx_flow=0, 
+
+tx_flow=[1|0]                    Specifies the Tx flow control. If tx_flow=0,
                                  the Tx flow control disable else driver
                                  autodetect.
-rx_flow=[1|0]                  - Specifies the Rx flow control. If rx_flow=0, 
+rx_flow=[1|0]                    Specifies the Rx flow control. If rx_flow=0,
                                  the Rx flow control enable else driver
                                  autodetect.
+===============================   ==============================================
 
 
 Configuration Script Sample
 ===========================
-Here is a sample of a simple configuration script:
+Here is a sample of a simple configuration script::
 
-DEVICE=eth0
-USERCTL=no
-ONBOOT=yes
-POOTPROTO=none
-BROADCAST=207.200.5.255
-NETWORK=207.200.5.0
-NETMASK=255.255.255.0
-IPADDR=207.200.5.2
+    DEVICE=eth0
+    USERCTL=no
+    ONBOOT=yes
+    POOTPROTO=none
+    BROADCAST=207.200.5.255
+    NETWORK=207.200.5.0
+    NETMASK=255.255.255.0
+    IPADDR=207.200.5.2
 
 
 Troubleshooting
 ===============
 Q1. Source files contain ^ M behind every line.
-       Make sure all files are Unix file format (no LF). Try the following
-    shell command to convert files.
+
+    Make sure all files are Unix file format (no LF). Try the following
+    shell command to convert files::
 
        cat dl2k.c | col -b > dl2k.tmp
        mv dl2k.tmp dl2k.c
 
-       OR
+    OR::
 
        cat dl2k.c | tr -d "\r" > dl2k.tmp
        mv dl2k.tmp dl2k.c
 
-Q2: Could not find header files (*.h) ?
-       To compile the driver, you need kernel header files. After
+Q2: Could not find header files (``*.h``)?
+
+    To compile the driver, you need kernel header files. After
     installing the kernel source, the header files are usually located in
     /usr/src/linux/include, which is the default include directory configured
     in Makefile. For some distributions, there is a copy of header files in
     /usr/src/include/linux and /usr/src/include/asm, that you can change the
     INCLUDEDIR in Makefile to /usr/include without installing kernel source.
-       Note that RH 7.0 didn't provide correct header files in /usr/include,
+
+    Note that RH 7.0 didn't provide correct header files in /usr/include,
     including those files will make a wrong version driver.