The event mask was specified as 0xF (4 bits) when in reality is 0x1F (5
bits) in order to be capable of representing all FIFO length values from
0 to 16.
This caused a problem: when the keypad reported 16 pending events the
driver took it as 0, and did nothing. This in turn caused the keypad to
re-issue the interrupt over and over again.
Signed-off-by: Guido MartÃnez <guido@vanguardiasur.com.ar>
Acked-by: Michael Hennerich <michael.hennerich@analog.com>
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
 #define LOGIC2_STAT    (1 << 7)        /* ADP5589 only */
 #define LOGIC1_STAT    (1 << 6)
 #define LOCK_STAT      (1 << 5)        /* ADP5589 only */
-#define KEC            0xF
+#define KEC            0x1F
 
 /* PIN_CONFIG_D Register */
 #define C4_EXTEND_CFG  (1 << 6)        /* RESET2 */