To ensure the stable clock need to enable before set the
DW_MMC_CARD_NEED_INIT flag.  If set DW_MMC_CARD_NEED_INIT flag,
wait for 80-clock before first command after power-up.
Signed-off-by: Jaehoon Chung <jh80.chung@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Acked-by: Seungwon Jeon <tgih.jun@samsung.com>
Acked-by: Will Newton <will.newton@imgtec.com>
Signed-off-by: Chris Ball <cjb@laptop.org>
        if (host->pdata->select_slot)
                host->pdata->select_slot(slot->id);
 
-       /* Slot specific timing and width adjustment */
-       dw_mci_setup_bus(slot, false);
-
        host->cur_slot = slot;
        host->mrq = mrq;
 
        if (drv_data && drv_data->set_ios)
                drv_data->set_ios(slot->host, ios);
 
+       /* Slot specific timing and width adjustment */
+       dw_mci_setup_bus(slot, false);
+
        switch (ios->power_mode) {
        case MMC_POWER_UP:
                set_bit(DW_MMC_CARD_NEED_INIT, &slot->flags);