When a RAID6 is converted to a RAID5, the extra drive should
be discarded.  However it isn't due to a typo in a comparison.
This bug was introduced in commit 
e93f68a1fc6 in 2.6.35-rc4
and is suitable for any -stable since than.
As the extra drive is not removed, the 'degraded' counter is wrong and
so the RAID5 will not respond correctly to a subsequent failure.
Cc: stable@kernel.org
Signed-off-by: NeilBrown <neilb@suse.de>
                char nm[20];
                if (rdev->raid_disk < 0)
                        continue;
-               if (rdev->new_raid_disk > mddev->raid_disks)
+               if (rdev->new_raid_disk >= mddev->raid_disks)
                        rdev->new_raid_disk = -1;
                if (rdev->new_raid_disk == rdev->raid_disk)
                        continue;