]> www.infradead.org Git - users/jedix/linux-maple.git/commitdiff
hpsa: add in new controllers
authorDon Brace <don.brace@pmcs.com>
Fri, 6 Nov 2015 14:04:54 +0000 (06:04 -0800)
committerChuck Anderson <chuck.anderson@oracle.com>
Thu, 10 Mar 2016 19:56:12 +0000 (11:56 -0800)
Signed-off-by: Don Brace <don.brace@pmcs.com>
Orabug: 22075051
Acked-by: Chuck Anderson <chuck.anderson@oracle.com>
drivers/scsi/hpsa.c

index d95762b88c35f300cb32756dcd5fa62a8c050e55..7f09b66d036e9629398c019d0f1f69df247eac3b 100644 (file)
@@ -129,6 +129,11 @@ static const struct pci_device_id hpsa_pci_device_id[] = {
        {PCI_VENDOR_ID_HP,     PCI_DEVICE_ID_HP_CISSI,     0x103C, 0x21CD},
        {PCI_VENDOR_ID_HP,     PCI_DEVICE_ID_HP_CISSI,     0x103C, 0x21CE},
        {PCI_VENDOR_ID_ADAPTEC2, 0x0290, 0x9005, 0x0580},
+       {PCI_VENDOR_ID_ADAPTEC2, 0x0290, 0x9005, 0x0581},
+       {PCI_VENDOR_ID_ADAPTEC2, 0x0290, 0x9005, 0x0582},
+       {PCI_VENDOR_ID_ADAPTEC2, 0x0290, 0x9005, 0x0583},
+       {PCI_VENDOR_ID_ADAPTEC2, 0x0290, 0x9005, 0x0584},
+       {PCI_VENDOR_ID_ADAPTEC2, 0x0290, 0x9005, 0x0585},
        {PCI_VENDOR_ID_HP_3PAR, 0x0075, 0x1590, 0x0076},
        {PCI_VENDOR_ID_HP_3PAR, 0x0075, 0x1590, 0x0087},
        {PCI_VENDOR_ID_HP_3PAR, 0x0075, 0x1590, 0x007D},
@@ -186,7 +191,12 @@ static struct board_type products[] = {
        {0x21CC103C, "Smart Array", &SA5_access},
        {0x21CD103C, "Smart Array", &SA5_access},
        {0x21CE103C, "Smart HBA", &SA5_access},
-       {0x05809005, "SmartHBA-SA", &SA5_access},
+       {0x05809005, "PM8068/69 SmartIOC-SA", &SA5_access},
+       {0x05819005, "PM8068/69 SmartIOC-SA 8i", &SA5_access},
+       {0x05829005, "PM8068/69 SmartIOC-SA 8i8e", &SA5_access},
+       {0x05839005, "PM8068/69 SmartIOC-SA 8e", &SA5_access},
+       {0x05849005, "PM8068/69 SmartIOC-SA 16i", &SA5_access},
+       {0x05859005, "PM8068/69 SmartIOC-SA 4i4e", &SA5_access},
        {0x00761590, "HP Storage P1224 Array Controller", &SA5_access},
        {0x00871590, "HP Storage P1224e Array Controller", &SA5_access},
        {0x007D1590, "HP Storage P1228 Array Controller", &SA5_access},