The _ART (Active Cooling Relationship Table), specifies relationship
among heat generating sources to a target active cooling device like
fan. The _ART table refers to actual bus id name for specifying relationship.
Naming "Fan" is not enough as name in the _ART table can change on every
platform, to establish relationship for user space thermal controllers.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
        struct thermal_cooling_device *cdev;
        struct acpi_fan *fan;
        struct acpi_device *device = ACPI_COMPANION(&pdev->dev);
+       char *name;
 
        fan = devm_kzalloc(&pdev->dev, sizeof(*fan), GFP_KERNEL);
        if (!fan) {
                }
        }
 
-       cdev = thermal_cooling_device_register("Fan", device,
+       if (!strncmp(pdev->name, "PNP0C0B", strlen("PNP0C0B")))
+               name = "Fan";
+       else
+               name = acpi_device_bid(device);
+
+       cdev = thermal_cooling_device_register(name, device,
                                                &fan_cooling_ops);
        if (IS_ERR(cdev)) {
                result = PTR_ERR(cdev);