The newly defined format for the `INSN_CONFIG_DIGITAL_TRIG`
configuration instruction expects 6 data values.  Check the length in
`check_insn_config_length()` before calling the comedi subdevice's
`insn_config` handler.
Signed-off-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
                if (insn->n == 5)
                        return 0;
                break;
+       case INSN_CONFIG_DIGITAL_TRIG:
+               if (insn->n == 6)
+                       return 0;
+               break;
                /* by default we allow the insn since we don't have checks for
                 * all possible cases yet */
        default: