When detecting zero in 'dbs' field of CIP header, this packet streaming
should be aborted because of avoiding division-by-zero. This is an error
in an aspect of IEC 61883-1, thus protocol error.
This commit use EPROTO instead of EIO. Actually, the returned value is
not used for userspace and this commit has no effect.
Signed-off-by: Takashi Sakamoto <o-takashi@sakamocchi.jp>
Acked-by: Clemens Ladisch <clemens@ladisch.de>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
                        dev_err(&s->unit->device,
                                "Detect invalid value in dbs field: %08X\n",
                                cip_header[0]);
-                       return -EIO;
+                       return -EPROTO;
                }
                if (s->flags & CIP_WRONG_DBS)
                        data_block_quadlets = s->data_block_quadlets;