We might as well configure the limit to default to 1 pool always for the
interface. This accounts for the fact that the PF counts as 1 pool if
SR-IOV is enabled, and in general we are always running in 1 pool mode when
RSS or DCB is enabled as well, though we don't need to actually evaluate
any of the VMDq features in those cases.
Signed-off-by: Alexander Duyck <alexander.h.duyck@intel.com>
Tested-by: Andrew Bowers <andrewx.bowers@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
        fdir = min_t(int, IXGBE_MAX_FDIR_INDICES, num_online_cpus());
        adapter->ring_feature[RING_F_FDIR].limit = fdir;
        adapter->fdir_pballoc = IXGBE_FDIR_PBALLOC_64K;
+       adapter->ring_feature[RING_F_VMDQ].limit = 1;
 #ifdef CONFIG_IXGBE_DCA
        adapter->flags |= IXGBE_FLAG_DCA_CAPABLE;
 #endif
 
        struct ixgbe_hw *hw = &adapter->hw;
        int i;
 
-       adapter->flags |= IXGBE_FLAG_SRIOV_ENABLED;
-
        /* Enable VMDq flag so device will be set in VM mode */
-       adapter->flags |= IXGBE_FLAG_VMDQ_ENABLED;
-       if (!adapter->ring_feature[RING_F_VMDQ].limit)
-               adapter->ring_feature[RING_F_VMDQ].limit = 1;
+       adapter->flags |= IXGBE_FLAG_SRIOV_ENABLED |
+                         IXGBE_FLAG_VMDQ_ENABLED;
 
        /* Allocate memory for per VF control structures */
        adapter->vfinfo = kcalloc(num_vfs, sizeof(struct vf_data_storage),