- interrupts: exactly one interrupt specifier
 
 Optional properties:
-- pinctrl: When present, must have one state named "sleep"
-          and one state named "default"
-- clocks:  When present, must refer to exactly one clock named
+- pinctrl: When present, must have one state named "default",
+          and may contain a second name named "sleep". The former
+          state sets up pins for ordinary operation whereas
+          the latter state will put the associated pins to sleep
+          when the UART is unused
+- clocks:  When present, the first clock listed must correspond to
+          the clock named UARTCLK on the IP block, i.e. the clock
+          to the external serial line, whereas the second clock
+          must correspond to the PCLK clocking the internal logic
+          of the block. Just listing one clock (the first one) is
+          deprecated.
+- clocks-names: When present, the first clock listed must be named
+          "uartclk" and the second clock listed must be named
           "apb_pclk"
 - dmas:           When present, may have one or two dma channels.
           The first one must be named "rx", the second one
           must be named "tx".
 
 See also bindings/arm/primecell.txt
+
+Example:
+
+uart@80120000 {
+       compatible = "arm,pl011", "arm,primecell";
+       reg = <0x80120000 0x1000>;
+       interrupts = <0 11 IRQ_TYPE_LEVEL_HIGH>;
+       dmas = <&dma 13 0 0x2>, <&dma 13 0 0x0>;
+       dma-names = "rx", "tx";
+       clocks = <&foo_clk>, <&bar_clk>;
+       clock-names = "uartclk", "apb_pclk";
+};