The subdev .s_stream() operation shall not be called to start streaming
on an already started subdev, or stop streaming on a stopped subdev.
Remove the check that guards against that condition.
Signed-off-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
Signed-off-by: Sakari Ailus <sakari.ailus@linux.intel.com>
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
        int ret = 0;
 
        mutex_lock(&ov08x->mutex);
-       if (ov08x->streaming == enable) {
-               mutex_unlock(&ov08x->mutex);
-               return 0;
-       }
 
        if (enable) {
                ret = pm_runtime_resume_and_get(&client->dev);