I found during some failure injection testing that the call to
rbd_free_disk() in the error path of rbd_dev_probe_finish() was
dropping an extra reference to the disk queue.  The problem
occurred when put_disk tried to drop a reference to the disk's
queue.  A call to blk_cleanup_queue() just prior to that will have
also dropped a reference to the queue.
The problem is that the reference dropped by put_disk() is assumed
to have been taken by add_disk().  Our code has error paths that can
occur after the disk and its queue are initialized, but before the
call to add_disk(), and in those paths we won't have that extra
reference.
The fix is easy though.  In rbd_free_disk() we're already checking
the disk's GENHD_FL_UP flag.  That flag is an indication that
add_disk() has been called, so just call blk_cleanup_queue()
conditional on that flag being set.
This resolves:
    http://tracker.ceph.com/issues/4800
Signed-off-by: Alex Elder <elder@inktank.com>
Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
        if (!disk)
                return;
 
-       if (disk->flags & GENHD_FL_UP)
+       rbd_dev->disk = NULL;
+       if (disk->flags & GENHD_FL_UP) {
                del_gendisk(disk);
-       if (disk->queue)
-               blk_cleanup_queue(disk->queue);
+               if (disk->queue)
+                       blk_cleanup_queue(disk->queue);
+       }
        put_disk(disk);
 }