R1_ADDRESS_ERROR |     /* Misaligned address */                \
         R1_BLOCK_LEN_ERROR |   /* Transferred block length incorrect */\
         R1_WP_VIOLATION |      /* Tried to write to protected block */ \
+        R1_CARD_ECC_FAILED |   /* Card ECC failed */                   \
         R1_CC_ERROR |          /* Card controller error */             \
         R1_ERROR)              /* General/unknown error */
 
+static bool mmc_blk_has_cmd_err(struct mmc_command *cmd)
+{
+       if (!cmd->error && cmd->resp[0] & CMD_ERRORS)
+               cmd->error = -EIO;
+
+       return cmd->error;
+}
+
 static enum mmc_blk_status mmc_blk_err_check(struct mmc_card *card,
                                             struct mmc_async_req *areq)
 {
         * stop.error indicates a problem with the stop command.  Data
         * may have been transferred, or may still be transferring.
         */
-       if (brq->sbc.error || brq->cmd.error || brq->stop.error ||
+       if (brq->sbc.error || brq->cmd.error || mmc_blk_has_cmd_err(&brq->stop) ||
            brq->data.error) {
                switch (mmc_blk_cmd_recovery(card, req, brq, &ecc_err, &gen_err)) {
                case ERR_RETRY: