mutex_lock(&data->update_lock);
 
+       data->sensor = it87_read_value(data, IT87_REG_TEMP_ENABLE);
        data->sensor &= ~(1 << nr);
        data->sensor &= ~(8 << nr);
        if (val == 2) { /* backwards compatibility */
                        it87_write_value(data, IT87_REG_TEMP_HIGH(i), 127);
        }
 
-       /* Check if temperature channels are reset manually or by some reason */
-       tmp = it87_read_value(data, IT87_REG_TEMP_ENABLE);
-       if ((tmp & 0x3f) == 0) {
-               /* Temp1,Temp3=thermistor; Temp2=thermal diode */
-               tmp = (tmp & 0xc0) | 0x2a;
-               it87_write_value(data, IT87_REG_TEMP_ENABLE, tmp);
-       }
-       data->sensor = tmp;
+       /* Temperature channels are not forcibly enabled, as they can be
+        * set to two different sensor types and we can't guess which one
+        * is correct for a given system. These channels can be enabled at
+        * run-time through the temp{1-3}_type sysfs accessors if needed. */
 
        /* Check if voltage monitors are reset manually or by some reason */
        tmp = it87_read_value(data, IT87_REG_VIN_ENABLE);