In the error handling path `out_acc` of `ubi_resize_volume()`,
when `pebs < 0`, it indicates that the volume table record failed to
update when the volume was shrunk. In this case, the number of `ubi->avail_pebs`
and `ubi->rsvd_pebs` should be restored to their previous values to prevent
the UBI layer from reporting an incorrect number of available PEBs.
Signed-off-by: ZhaoLong Wang <wangzhaolong1@huawei.com>
Reviewed-by: Zhihao Cheng <chengzhihao1@huawei.com>
Signed-off-by: Richard Weinberger <richard@nod.at>
 out_acc:
        spin_lock(&ubi->volumes_lock);
        vol->reserved_pebs = reserved_pebs - pebs;
-       if (pebs > 0) {
-               ubi->rsvd_pebs -= pebs;
-               ubi->avail_pebs += pebs;
+       ubi->rsvd_pebs -= pebs;
+       ubi->avail_pebs += pebs;
+       if (pebs > 0)
                ubi_eba_copy_table(vol, old_eba_tbl, vol->reserved_pebs);
-       } else {
+       else
                ubi_eba_copy_table(vol, old_eba_tbl, reserved_pebs);
-       }
        vol->eba_tbl = old_eba_tbl;
        spin_unlock(&ubi->volumes_lock);
 out_free: