return ret;
        }
 
-       /* Disable PU power down in normal operation if ERR009619 is present */
+       /*
+        * Disable PU power down by runtime PM if ERR009619 is present.
+        *
+        * The PRE clock will be paused for several cycles when turning on the
+        * PU domain LDO from power down state. If PRE is in use at that time,
+        * the IPU/PRG cannot get the correct display data from the PRE.
+        *
+        * This is not a concern when the whole system enters suspend state, so
+        * it's safe to power down PU in this case.
+        */
        if (of_id_data->err009619_present)
                imx_gpc_domains[GPC_PGC_DOMAIN_PU].base.flags |=
-                               GENPD_FLAG_ALWAYS_ON;
+                               GENPD_FLAG_RPM_ALWAYS_ON;
 
        /* Keep DISP always on if ERR006287 is present */
        if (of_id_data->err006287_present)