The reboot and poweroff features are actually part of the Power
Management Unit system controller, thus allow them as its children,
instead of specifying as separate device nodes with syscon phandle.
Without it, the reboot/poweroff feature becomes unavailable.
Signed-off-by: Binbin Zhou <zhoubinbin@loongson.cn>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
       addition, the PM need according to it to indicate that current
       SoC whether support Suspend To RAM.
 
+  syscon-poweroff:
+    $ref: /schemas/power/reset/syscon-poweroff.yaml#
+    type: object
+    description:
+      Node for power off method
+
+  syscon-reboot:
+    $ref: /schemas/power/reset/syscon-reboot.yaml#
+    type: object
+    description:
+      Node for reboot method
+
 required:
   - compatible
   - reg
         interrupt-parent = <&liointc1>;
         interrupts = <11 IRQ_TYPE_LEVEL_LOW>;
         loongson,suspend-address = <0x0 0x1c000500>;
+
+        syscon-reboot {
+            compatible = "syscon-reboot";
+            offset = <0x30>;
+            mask = <0x1>;
+        };
+
+        syscon-poweroff {
+            compatible = "syscon-poweroff";
+            regmap = <&pmc>;
+            offset = <0x14>;
+            mask = <0x3c00>;
+            value = <0x3c00>;
+        };
     };