The head-of-line blocking timer should only be modified when
head-of-line drop is disabled.
One of the steps in recovering from a modem crash is to enable
dropping of packets with timeout of 0 (immediate).  We don't know
how the modem configured its endpoints, so before we program the
timer, we need to ensure HOL_BLOCK is disabled.
Fixes: 84f9bd12d46db ("soc: qcom: ipa: IPA endpoints")
Signed-off-by: Alex Elder <elder@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
        u32 offset;
        u32 val;
 
+       /* This should only be changed when HOL_BLOCK_EN is disabled */
        offset = IPA_REG_ENDP_INIT_HOL_BLOCK_TIMER_N_OFFSET(endpoint_id);
        val = hol_block_timer_val(ipa, microseconds);
        iowrite32(val, ipa->reg_virt + offset);
                if (endpoint->toward_ipa || endpoint->ee_id != GSI_EE_MODEM)
                        continue;
 
+               ipa_endpoint_init_hol_block_enable(endpoint, false);
                ipa_endpoint_init_hol_block_timer(endpoint, 0);
                ipa_endpoint_init_hol_block_enable(endpoint, true);
        }