profile which is also the profile that's active on device startup.
                When written this attribute activates the selected profile
                immediately.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/arvo/roccatarvo<minor>/button
 Date:          Januar 2011
                button for a specific profile. Button and profile numbers are
                included in written data. The data has to be 24 bytes long.
                This file is writeonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/arvo/roccatarvo<minor>/info
 Date:          Januar 2011
                installed firmware version.
                The size of the data is 8 bytes in size.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/arvo/roccatarvo<minor>/key_mask
 Date:          Januar 2011
                When read, this file returns the current state of the buttons.
                When written, the given buttons are activated/deactivated
                immediately.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/arvo/roccatarvo<minor>/mode_key
 Date:          Januar 2011
                the assignment of the number block changes.
                The integer value of this attribute ranges from 0 (OFF) to 1 (ON).
                When read, this file returns the actual state of the key.
-               When written, the key is activated/deactivated immediately.
\ No newline at end of file
+               When written, the key is activated/deactivated immediately.
+Users:         http://roccat.sourceforge.net
 
                6     3200
 
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kone/roccatkone<minor>/actual_profile
 Date:          March 2010
 Contact:       Stefan Achatz <erazor_de@users.sourceforge.net>
 Description:   When read, this file returns the number of the actual profile.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kone/roccatkone<minor>/firmware_version
 Date:          March 2010
                number the decimal point has to be shifted 2 positions to the
                left. E.g. a returned value of 138 means 1.38
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kone/roccatkone<minor>/profile[1-5]
 Date:          March 2010
                The mouse will reject invalid data, whereas the profile number
                stored in the profile doesn't need to fit the number of the
                store.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kone/roccatkone<minor>/settings
 Date:          March 2010
                When written, this file lets write settings back to the mouse.
                The data has to be 36 bytes long. The mouse will reject invalid
                data.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kone/roccatkone<minor>/startup_profile
 Date:          March 2010
                 that's active when the mouse is powered on.
                When written, this file sets the number of the startup profile
                and the mouse activates this profile immediately.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kone/roccatkone<minor>/tcu
 Date:          March 2010
                Writing 0 in this file will switch the TCU off.
                Writing 1 in this file will start the calibration which takes
                around 6 seconds to complete and activates the TCU.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kone/roccatkone<minor>/weight
 Date:          March 2010
                4     20g
 
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 Description:   When read, this file returns the number of the actual profile in
                range 0-4.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/firmware_version
 Date:          October 2010
                number the decimal point has to be shifted 2 positions to the
                left. E.g. a returned value of 121 means 1.21
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/macro
 Date:          October 2010
                button for a specific profile. Button and profile numbers are
                included in written data. The data has to be 2082 bytes long.
                This file is writeonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/profile_buttons
 Date:          August 2010
                Which profile to write is determined by the profile number
                contained in the data.
                This file is writeonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/profile[1-5]_buttons
 Date:          August 2010
                When read, these files return the respective profile buttons.
                The returned data is 77 bytes in size.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/profile_settings
 Date:          October 2010
                Which profile to write is determined by the profile number
                contained in the data.
                This file is writeonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/profile[1-5]_settings
 Date:          August 2010
                When read, these files return the respective profile settings.
                The returned data is 43 bytes in size.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/sensor
 Date:          October 2010
                can be activated/deactivated and the lift-off distance can be
                set. The data has to be 6 bytes long.
                This file is writeonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/startup_profile
 Date:          October 2010
                 that's active when the mouse is powered on.
                When written, this file sets the number of the startup profile
                and the mouse activates this profile immediately.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/tcu
 Date:          October 2010
                can be initiated/cancelled.
                The data has to be 3 bytes long.
                This file is writeonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/tcu_image
 Date:          October 2010
                calibration process initiated with tcu.
                The returned data is 1028 bytes in size.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
                When read, this attribute returns the number of the active
                cpi level.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/actual_profile
 Date:          January 2011
                When written, the mouse activates this profile immediately.
                The profile that's active when powered down is the same that's
                active when the mouse is powered on.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/actual_sensitivity_x
 Date:          January 2011
                When read, this attribute returns the number of the actual
                sensitivity in x direction.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/actual_sensitivity_y
 Date:          January 2011
                When read, this attribute returns the number of the actual
                sensitivity in y direction.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/firmware_version
 Date:          January 2011
                number the decimal point has to be shifted 2 positions to the
                left. E.g. a returned value of 121 means 1.21
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/profile_buttons
 Date:          January 2011
                Which profile to write is determined by the profile number
                contained in the data.
                This file is writeonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/profile[1-5]_buttons
 Date:          January 2011
                When read, these files return the respective profile buttons.
                The returned data is 23 bytes in size.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/profile_settings
 Date:          January 2011
                Which profile to write is determined by the profile number
                contained in the data.
                This file is writeonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/kovaplus/roccatkovaplus<minor>/profile[1-5]_settings
 Date:          January 2011
                When read, these files return the respective profile settings.
                The returned data is 16 bytes in size.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
                4     1600
 
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/pyra/roccatpyra<minor>/actual_profile
 Date:          August 2010
 Description:   When read, this file returns the number of the actual profile in
                range 0-4.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/pyra/roccatpyra<minor>/firmware_version
 Date:          August 2010
                number the decimal point has to be shifted 2 positions to the
                left. E.g. a returned value of 138 means 1.38
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/pyra/roccatpyra<minor>/profile_settings
 Date:          August 2010
                Which profile to write is determined by the profile number
                contained in the data.
                This file is writeonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/pyra/roccatpyra<minor>/profile[1-5]_settings
 Date:          August 2010
                When read, these files return the respective profile settings.
                The returned data is 13 bytes in size.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/pyra/roccatpyra<minor>/profile_buttons
 Date:          August 2010
                Which profile to write is determined by the profile number
                contained in the data.
                This file is writeonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/pyra/roccatpyra<minor>/profile[1-5]_buttons
 Date:          August 2010
                When read, these files return the respective profile buttons.
                The returned data is 19 bytes in size.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/pyra/roccatpyra<minor>/startup_profile
 Date:          August 2010
                 When read, this attribute returns the number of the profile
                 that's active when the mouse is powered on.
                This file is readonly.
+Users:         http://roccat.sourceforge.net
 
 What:          /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/pyra/roccatpyra<minor>/settings
 Date:          August 2010
                When written, this file lets write settings back to the mouse.
                The data has to be 3 bytes long. The mouse will reject invalid
                data.
+Users:         http://roccat.sourceforge.net