If a device is hot unplgged during EEH recovery, it's possible for the
RTAS call to ibm,configure-pe in pseries_eeh_configure() to return
parameter error (-3), however negative return values are not checked
for and this leads to an infinite loop.
Fix this by correctly bailing out on negative values.
Signed-off-by: Sam Bobroff <sbobroff@linux.ibm.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Reviewed-by: Nathan Lynch <nathanl@linux.ibm.com>
Link: https://lore.kernel.org/r/1b0a6010a647dc915816e44845b64d72066676a7.1588045502.git.sbobroff@linux.ibm.com
 
                if (!ret)
                        return ret;
+               if (ret < 0)
+                       break;
 
                /*
                 * If RTAS returns a delay value that's above 100ms, cut it
 
        pr_warn("%s: Unable to configure bridge PHB#%x-PE#%x (%d)\n",
                __func__, pe->phb->global_number, pe->addr, ret);
-       return ret;
+       /* PAPR defines -3 as "Parameter Error" for this function: */
+       if (ret == -3)
+               return -EINVAL;
+       else
+               return -EIO;
 }
 
 /**