This patch updates some description strings for BEx/Skyhawk-R
UE (unrecoverable error) status register bits. The appropriate strings
are logged when a UE is detected in the adapter.
Signed-off-by: Vasundhara Volam <vasundhara.volam@emulex.com>
Signed-off-by: Sathya Perla <sathya.perla@emulex.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
        "P1_OB_LINK ",
        "HOST_GPIO ",
        "MBOX ",
-       "AXGMAC0",
-       "AXGMAC1",
-       "JTAG",
-       "MPU_INTPEND"
+       "ERX2 ",
+       "SPARE ",
+       "JTAG ",
+       "MPU_INTPEND "
 };
 /* UE Status High CSR */
 static const char * const ue_status_hi_desc[] = {
        "HOST5",
        "HOST6",
        "HOST7",
-       "HOST8",
-       "HOST9",
+       "ECRC",
+       "Poison TLP",
        "NETC",
-       "Unknown",
-       "Unknown",
-       "Unknown",
-       "Unknown",
-       "Unknown",
-       "Unknown",
-       "Unknown",
+       "PERIPH",
+       "LLTXULP",
+       "D2P",
+       "RCON",
+       "LDMA",
+       "LLTXP",
+       "LLTXPB",
        "Unknown"
 };