The LIS3LV02 has a special bit that need to be set to get the
read values left aligned. Before this patch we get gibberish
like this:
iio_generic_buffer -a -c10 -n lis3lv02dl_accel
(...)
0.000000 -0.010042 -0.642688 
19155832931907
0.000000 -0.010042 -0.642688 
19155858751073
Which is because we read a raw value for 1g as 64 which is
the nominal 1024 for 1g shifted 4 bits to the left by being
right-aligned rather than left aligned.
Since all other sensors are left aligned, add some code to
set the special DAS (data alignment setting) bit to 1 so that
the right value is now read like this:
iio_generic_buffer -a -c10 -n lis3lv02dl_accel
(...)
0.000000 -0.147095 -10.120135 
24761614364956
-0.029419 -0.176514 -10.120135 
24761631624540
The scaling was weird as well: we have a gain of 1000 for 1g
and 3000 for 6g. I don't even remember how I came up with the
old values but they are wrong.
Fixes: 3acddf74f807 ("iio: st-sensors: add support for lis3lv02d accelerometer")
Cc: Lorenzo Bianconi <lorenzo.bianconi@st.com>
Cc: Giuseppe Barba <giuseppe.barba@st.com>
Cc: Denis Ciocca <denis.ciocca@st.com>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
                                [0] = {
                                        .num = ST_ACCEL_FS_AVL_2G,
                                        .value = 0x00,
-                                       .gain = IIO_G_TO_M_S_2(1024),
+                                       .gain = IIO_G_TO_M_S_2(1000),
                                },
                                [1] = {
                                        .num = ST_ACCEL_FS_AVL_6G,
                                        .value = 0x01,
-                                       .gain = IIO_G_TO_M_S_2(340),
+                                       .gain = IIO_G_TO_M_S_2(3000),
                                },
                        },
                },
                        .addr = 0x21,
                        .mask = 0x40,
                },
+               /*
+                * Data Alignment Setting - needs to be set to get
+                * left-justified data like all other sensors.
+                */
+               .das = {
+                       .addr = 0x21,
+                       .mask = 0x01,
+               },
                .drdy_irq = {
                        .addr = 0x21,
                        .mask_int1 = 0x04,
 
                        return err;
        }
 
+       /* set DAS */
+       if (sdata->sensor_settings->das.addr) {
+               err = st_sensors_write_data_with_mask(indio_dev,
+                                       sdata->sensor_settings->das.addr,
+                                       sdata->sensor_settings->das.mask, 1);
+               if (err < 0)
+                       return err;
+       }
+
        if (sdata->int_pin_open_drain) {
                dev_info(&indio_dev->dev,
                         "set interrupt line to open drain mode\n");
 
        u8 mask;
 };
 
+/**
+ * struct st_sensor_das - ST sensor device data alignment selection
+ * @addr: address of the register.
+ * @mask: mask to write the das flag for left alignment.
+ */
+struct st_sensor_das {
+       u8 addr;
+       u8 mask;
+};
+
 /**
  * struct st_sensor_data_ready_irq - ST sensor device data-ready interrupt
  * @addr: address of the register.
  * @enable_axis: Enable one or more axis of the sensor.
  * @fs: Full scale register and full scale list available.
  * @bdu: Block data update register.
+ * @das: Data Alignment Selection register.
  * @drdy_irq: Data ready register of the sensor.
  * @multi_read_bit: Use or not particular bit for [I2C/SPI] multi-read.
  * @bootime: samples to discard when sensor passing from power-down to power-up.
        struct st_sensor_axis enable_axis;
        struct st_sensor_fullscale fs;
        struct st_sensor_bdu bdu;
+       struct st_sensor_das das;
        struct st_sensor_data_ready_irq drdy_irq;
        bool multi_read_bit;
        unsigned int bootime;