We need to flush the msgr workqueue during mon_client shutdown to
ensure that any work affecting our embedded ceph_connection is
finished so that we can be safely destroyed.
Previously, we were flushing the work queue after osd_client
shutdown and before mon_client shutdown to ensure that any osd
connection refs to authorizers are flushed.  Remove the redundant
flush, and document in the comment that the mon_client flush is
needed to cover that case as well.
Signed-off-by: Sage Weil <sage@inktank.com>
Reviewed-by: Alex Elder <elder@inktank.com>
(cherry picked from commit 
f3dea7edd3d449fe7a6d402c1ce56a294b985261)
        /* unmount */
        ceph_osdc_stop(&client->osdc);
 
-       /*
-        * make sure osd connections close out before destroying the
-        * auth module, which is needed to free those connections'
-        * ceph_authorizers.
-        */
-       ceph_msgr_flush();
-
        ceph_monc_stop(&client->monc);
 
        ceph_debugfs_client_cleanup(client);
 
 
        mutex_unlock(&monc->mutex);
 
+       /*
+        * flush msgr queue before we destroy ourselves to ensure that:
+        *  - any work that references our embedded con is finished.
+        *  - any osd_client or other work that may reference an authorizer
+        *    finishes before we shut down the auth subsystem.
+        */
+       ceph_msgr_flush();
+
        ceph_auth_destroy(monc->auth);
 
        ceph_msg_put(monc->m_auth);