STA control register has areas of mode and opcodes for opeations. 18 bit is
using for mode selection, where 0 is old MIO/MDIO access method and 1 is
indirect access mode. 19-20 bits are using for setting up read/write
operation(STA opcodes). In current state 'read' is set into old MIO/MDIO mode
with 19 bit and write operation is set into 18 bit which is mode selection,
not a write operation. To correlate write with read we set it into 20 bit.
All those bit operations are MSB 0 based.
Signed-off-by: Ivan Mikhaylov <ivan@de.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
 #define EMAC_STACR_PHYE                        0x00004000
 #define EMAC_STACR_STAC_MASK           0x00003000
 #define EMAC_STACR_STAC_READ           0x00001000
-#define EMAC_STACR_STAC_WRITE          0x00002000
+#define EMAC_STACR_STAC_WRITE          0x00000800
 #define EMAC_STACR_OPBC_MASK           0x00000C00
 #define EMAC_STACR_OPBC_50             0x00000000
 #define EMAC_STACR_OPBC_66             0x00000400