PHY_CONTROL register works as defined in the IEEE 802.3 specification
(IEEE 802.3-2008 22.2.4.1). Tidy up the temporary workaround.
User impact: PHY can now be powered down when the ethernet link is down.
Testing hints: ip link set down <device> (or just disconnect the
ethernet cable).
Oldest tested NVM version is: 1045:740.
Fixes: 5586838fe9ce ("igc: Add code for PHY support")
Signed-off-by: Sasha Neftin <sasha.neftin@intel.com>
Reviewed-by: Paul Menzel <pmenzel@molgen.mpg.de>
Tested-by: Naama Meir <naamax.meir@linux.intel.com>
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>
/* The PHY will retain its settings across a power down/up cycle */
hw->phy.ops.read_reg(hw, PHY_CONTROL, &mii_reg);
mii_reg |= MII_CR_POWER_DOWN;
-
- /* Temporary workaround - should be removed when PHY will implement
- * IEEE registers as properly
- */
- /* hw->phy.ops.write_reg(hw, PHY_CONTROL, mii_reg);*/
+ hw->phy.ops.write_reg(hw, PHY_CONTROL, mii_reg);
usleep_range(1000, 2000);
}