        void *conf_data;
        int conf_len, conf_data_saved;
-       int rc;
+       int rc, path_err;
        __u8 lpm, opm;
        struct dasd_eckd_private *private, path_private;
        struct dasd_path *path_data;
        path_data = &device->path_data;
        opm = ccw_device_get_path_mask(device->cdev);
        conf_data_saved = 0;
+       path_err = 0;
        /* get configuration data per operational path */
        for (lpm = 0x80; lpm; lpm>>= 1) {
                if (!(lpm & opm))
                                        "the same device, path %02X leads to "
                                        "device %s instead of %s\n", lpm,
                                        print_path_uid, print_device_uid);
-                               return -EINVAL;
+                               path_err = -EINVAL;
+                               continue;
                        }
 
                        path_private.conf_data = NULL;
                        kfree(conf_data);
        }
 
-       return 0;
+       return path_err;
 }
 
 static int verify_fcx_max_data(struct dasd_device *device, __u8 lpm)
        private = (struct dasd_eckd_private *) device->private;
 
        /* Read Configuration Data */
-       rc = dasd_eckd_read_conf(device);
-       if (rc)
-               goto out_err;
+       dasd_eckd_read_conf(device);
 
        dasd_eckd_get_uid(device, &temp_uid);
        /* Generate device unique id */
        dasd_eckd_validate_server(device, DASD_CQR_FLAGS_FAILFAST);
 
        /* RE-Read Configuration Data */
-       rc = dasd_eckd_read_conf(device);
-       if (rc)
-               goto out_err;
+       dasd_eckd_read_conf(device);
 
        /* Read Feature Codes */
        dasd_eckd_read_features(device);