enum {
        ACPI_BATTERY_ALARM_PRESENT,
        ACPI_BATTERY_XINFO_PRESENT,
-       /* For buggy DSDTs that report negative 16-bit values for either
-        * charging or discharging current and/or report 0 as 65536
-        * due to bad math.
-        */
-       ACPI_BATTERY_QUIRK_SIGNED16_CURRENT,
        ACPI_BATTERY_QUIRK_PERCENTAGE_CAPACITY,
 };
 
        battery->update_time = jiffies;
        kfree(buffer.pointer);
 
-       if (test_bit(ACPI_BATTERY_QUIRK_SIGNED16_CURRENT, &battery->flags) &&
-           battery->rate_now != -1)
+       /* For buggy DSDTs that report negative 16-bit values for either
+        * charging or discharging current and/or report 0 as 65536
+        * due to bad math.
+        */
+       if (battery->power_unit == ACPI_BATTERY_POWER_UNIT_MA &&
+               battery->rate_now != ACPI_BATTERY_VALUE_UNKNOWN &&
+               (s16)(battery->rate_now) < 0) {
                battery->rate_now = abs((s16)battery->rate_now);
+               printk_once(KERN_WARNING FW_BUG "battery: (dis)charge rate"
+                       " invalid.\n");
+       }
 
        if (test_bit(ACPI_BATTERY_QUIRK_PERCENTAGE_CAPACITY, &battery->flags)
            && battery->capacity_now >= 0 && battery->capacity_now <= 100)
        battery->bat.dev = NULL;
 }
 
-static void acpi_battery_quirks(struct acpi_battery *battery)
-{
-       if (dmi_name_in_vendors("Acer") &&
-               battery->power_unit == ACPI_BATTERY_POWER_UNIT_MA) {
-               set_bit(ACPI_BATTERY_QUIRK_SIGNED16_CURRENT, &battery->flags);
-       }
-}
-
 /*
  * According to the ACPI spec, some kinds of primary batteries can
  * report percentage battery remaining capacity directly to OS.
                result = acpi_battery_get_info(battery);
                if (result)
                        return result;
-               acpi_battery_quirks(battery);
                acpi_battery_init_alarm(battery);
        }
        if (!battery->bat.dev)