[Why]
Need to implement register programming for HDR dynamic
metadata transmission and tests.
Signed-off-by: Ilya Bakoulin <Ilya.Bakoulin@amd.com>
Reviewed-by: Eric Bernstein <Eric.Bernstein@amd.com>
Acked-by: Leo Li <sunpeng.li@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
  *
  *   Ensure the OTG master update lock is set when changing DME configuration.
  */
-static void enc2_set_dynamic_metadata(struct stream_encoder *enc,
+void enc2_set_dynamic_metadata(struct stream_encoder *enc,
                bool enable_dme,
                uint32_t hubp_requestor_id,
                enum dynamic_metadata_mode dmdata_mode)
 
        struct stream_encoder *enc,
        const struct encoder_unblank_param *param);
 
+void enc2_set_dynamic_metadata(struct stream_encoder *enc,
+               bool enable_dme,
+               uint32_t hubp_requestor_id,
+               enum dynamic_metadata_mode dmdata_mode);
+
 #endif /* __DC_STREAM_ENCODER_DCN20_H__ */