A chip returning 0x00 in all registers is erroneously detected
as LM75. Check hysteresis and temperature limit registers and
abort if both are 0 to reduce the likelyhood for this to happen.
Reviewed-by: Rob Coulson <rob.coulson@gmail.com>
Reviewed-by: Jean Delvare <jdelvare@suse.de>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
                 || i2c_smbus_read_byte_data(new_client, 7) != os)
                        return -ENODEV;
        }
+       /*
+        * It is very unlikely that this is a LM75 if both
+        * hysteresis and temperature limit registers are 0.
+        */
+       if (hyst == 0 && os == 0)
+               return -ENODEV;
 
        /* Addresses cycling */
        for (i = 8; i <= 248; i += 40) {