struct device *dev = sensor->dev;
struct fwnode_handle *ep_fwnode;
struct gpio_desc *gpio;
- unsigned int rate = 0;
int i, ret;
/*
sensor->pwdn_gpio = gpio;
- sensor->xvclk = devm_clk_get_optional(dev, "xvclk");
+ sensor->xvclk = devm_v4l2_sensor_clk_get(dev, "xvclk");
if (IS_ERR(sensor->xvclk)) {
ret = dev_err_probe(dev, PTR_ERR(sensor->xvclk),
"xvclk clock missing or invalid\n");
goto out_free_bus_cfg;
}
- /*
- * We could have either a 24MHz or 19.2MHz clock rate from either DT or
- * ACPI... but we also need to support the weird IPU3 case which will
- * have an external clock AND a clock-frequency property. Check for the
- * clock-frequency property and if found, set that rate if we managed
- * to acquire a clock. This should cover the ACPI case. If the system
- * uses devicetree then the configured rate should already be set, so
- * we can just read it.
- */
- ret = fwnode_property_read_u32(dev_fwnode(dev), "clock-frequency",
- &rate);
- if (ret && !sensor->xvclk) {
- dev_err_probe(dev, ret, "invalid clock config\n");
- goto out_free_bus_cfg;
- }
-
- if (!ret && sensor->xvclk) {
- ret = clk_set_rate(sensor->xvclk, rate);
- if (ret) {
- dev_err_probe(dev, ret, "failed to set clock rate\n");
- goto out_free_bus_cfg;
- }
- }
-
- sensor->xvclk_freq = rate ?: clk_get_rate(sensor->xvclk);
+ sensor->xvclk_freq = clk_get_rate(sensor->xvclk);
for (i = 0; i < ARRAY_SIZE(ov2680_xvclk_freqs); i++) {
if (sensor->xvclk_freq == ov2680_xvclk_freqs[i])