With bi-directional stress traffic, the receiver could hang causing the
hardware to stop and a "Detected Tx Unit Hang" message dumped to the system
logfile.  Temporarily workaround this issue by disabling Tx flow control by
default.  The issue is currently being investigated and a follow-on patch
will be provided to revert this when it is resolved.
Signed-off-by: Bruce Allan <bruce.w.allan@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
         * the default flow control setting, so we explicitly
         * set it to full.
         */
-       if (hw->fc.requested_mode == e1000_fc_default)
-               hw->fc.requested_mode = e1000_fc_full;
+       if (hw->fc.requested_mode == e1000_fc_default) {
+               /* Workaround h/w hang when Tx flow control enabled */
+               if (hw->mac.type == e1000_pchlan)
+                       hw->fc.requested_mode = e1000_fc_rx_pause;
+               else
+                       hw->fc.requested_mode = e1000_fc_full;
+       }
 
        /*
         * Save off the requested flow control mode for use later.  Depending