Noisefloor values read on AR9271 are unreliable if they
are less than -114, set those statically to -116.
Signed-off-by: Sujith <Sujith.Manoharan@atheros.com>
Signed-off-by: Vasanthakumar Thiagarajan <vasanth@atheros.com>
Signed-off-by: Luis R. Rodriguez <lrodriguez@atheros.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
                nf = 0 - ((nf ^ 0x1ff) + 1);
        ath_print(common, ATH_DBG_CALIBRATE,
                  "NF calibrated [ctl] [chain 0] is %d\n", nf);
+
+       if (AR_SREV_9271(ah) && (nf >= -114))
+               nf = -116;
+
        nfarray[0] = nf;
 
        if (!AR_SREV_9285(ah) && !AR_SREV_9271(ah)) {
                nf = 0 - ((nf ^ 0x1ff) + 1);
        ath_print(common, ATH_DBG_CALIBRATE,
                  "NF calibrated [ext] [chain 0] is %d\n", nf);
+
+       if (AR_SREV_9271(ah) && (nf >= -114))
+               nf = -116;
+
        nfarray[3] = nf;
 
        if (!AR_SREV_9285(ah) && !AR_SREV_9271(ah)) {