The legacy serial driver does not work with an 8250 type UART that is
described in the device tree with the reg-offset and reg-shift
properties.  This change makes legacy_serial ignore these devices.
Signed-off-by: John Linn <john.linn@xilinx.com>
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
        if (of_get_property(np, "clock-frequency", NULL) == NULL)
                return -1;
 
+       /* if reg-shift or offset, don't try to use it */
+       if ((of_get_property(np, "reg-shift", NULL) != NULL) ||
+               (of_get_property(np, "reg-offset", NULL) != NULL))
+               return -1;
+
        /* if rtas uses this device, don't try to use it as well */
        if (of_get_property(np, "used-by-rtas", NULL) != NULL)
                return -1;