As per the Host Controller Standard Specification Version 4.20,
limitation of tuning iteration count is removed as PLL locking
time can be longer than UHS-1 tuning due to larger PVT fluctuation
and it will result in increase of tuning iteration to complete the
tuning.
This patch creates sdhci_host member tuning_loop_count to allow
hosts to specify maximum tuning iterations and also updates
execute_tuning to use this specified maximum tuning iteration count.
Default tuning_loop_count is set to same as existing loop count of
MAX_TUNING_LOOP which is 40 iterations.
Tested-by: Jon Hunter <jonathanh@nvidia.com>
Signed-off-by: Sowjanya Komatineni <skomatineni@nvidia.com>
Acked-by: Adrian Hunter <adrian.hunter@intel.com>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
 
        /*
         * Issue opcode repeatedly till Execute Tuning is set to 0 or the number
-        * of loops reaches 40 times.
+        * of loops reaches tuning loop count.
         */
-       for (i = 0; i < MAX_TUNING_LOOP; i++) {
+       for (i = 0; i < host->tuning_loop_count; i++) {
                u16 ctrl;
 
                sdhci_send_tuning(host, opcode);
        host->cqe_err_ier = SDHCI_CQE_INT_ERR_MASK;
 
        host->tuning_delay = -1;
+       host->tuning_loop_count = MAX_TUNING_LOOP;
 
        host->sdma_boundary = SDHCI_DEFAULT_BOUNDARY_ARG;
 
 
 #define SDHCI_TUNING_MODE_3    2
        /* Delay (ms) between tuning commands */
        int                     tuning_delay;
+       int                     tuning_loop_count;
 
        /* Host SDMA buffer boundary. */
        u32                     sdma_boundary;